RegVault

UN R153 Supplement 2 (00 series) · UNECE Regulation No. 153 (ECE R153) — Uniform provisions concerning the approval of vehicles with regard to fuel system integrity and safety of electric power train in the event of a rear-end collision.

UN R153 — Supplement 2 to the 00 series of amendments

Supplement 1 → 2

Adopted at the WP.29 185th sessionEntry into force 2022-06-22
What changed
  • The “Specific voltage condition” definition in paragraph 2.31. has a new Note 2. For pulsating DC voltages (alternating voltages without change of polarity), the DC threshold must be applied.
  • The existing note of paragraph 2.31. is renumbered as Note 1.
Why
  • The expert from CLEPA introduced the proposal to align UN Regulations Nos. 94, 95, 137 and 153.
  • The clarification of the “special voltage condition” definition aims to avoid misinterpretation in the isolation resistance test after exposure to water.

Q1What changed2 changes

DC threshold for pulsating DC voltages in the “Specific voltage condition” (para. 2.31.)

Paragraph 2.31. defines the “Specific voltage condition”. New Note 2 says that for pulsating DC voltages (alternating voltages without change of polarity), the DC threshold must be applied. The existing note of paragraph 2.31. is renumbered as Note 1.

Note 2 : For pulsating DC voltages (alternating voltages without change of polarity) the DC threshold shall be applied.
Note 1 : When a DC live part of such an electrical circuit is connected to chassis and the specific voltage condition applies, the maximum voltage between any live part and the electrical chassis is ≤ 30 V AC (rms) and ≤ 60 V DC.
See every change side by side in Compare

Q2Why it changed

Proposed by
Expert from CLEPA the European Association of Automotive Suppliers
Working party
GRSP, 69th session (May 2021)

Reasons

  • The expert from CLEPA introduced the proposal to align UN Regulations Nos. 94, 95, 137 and 153.

    Source
    “the expert from CLEPA introduced GRSP-69-41, to align UN Regulations Nos. 94, 95, 137 and 153”
  • Proposer's reason (informal document GRSP-69-41)

    With document GRSP-69-04, CLEPA proposed to clarify the “special voltage condition” definition in the 03 series of UN Regulation No. 100. The aim was to avoid misinterpretation in the application of the isolation resistance test after exposure to water. According to CLEPA, this would be critical for certain 48V air cooled motor generators having an integrated AD/DC voltage. CLEPA says that the same clarification is necessary in all other UN Regulations with the same definition.

    Submitted by Expert from CLEPA the European Association of Automotive Suppliers. Working party adoption: ECE/TRANS/WP.29/GRSP/69, para. 47.

    Sources (3)
    “CLEPA with document GRSP-69-04 proposed to amend the 03 series of Regulation 100 to clarify the definition 2.42 “special voltage condition””
    “avoid mis-interpretation in the application of the isolation resistance test after exposure to water which would result critical for certain 48V air cooled motor generators having and integrated AD/DC voltage”
    “Consequently it is necessary to introduce the same clarification in all other UN Regulations having the same “special voltage condition” definition.”

Document trail

  1. —ProposalGRSP-69-41Proposal by the expert from CLEPA
  2. —Working party adoptsECE/TRANS/WP.29/GRSP/69Session report, para. 47 and Annex X
  3. 2021-09Sent to WP.29ECE/TRANS/WP.29/2021/127Text that GRSP sent to WP.29 and AC.1
  4. 2021-11WP.29 adoptsECE/TRANS/WP.29/1161Adopted at the 185th session (session report, para. 121)
  5. 2022-06-22In forceC.N.252.2022.TREATIES-XI.B.16.153UN depositary notification

Q3Who is affected

Vehicle manufacturer

  • For the “Specific voltage condition”, apply the DC threshold to pulsating DC voltages (alternating voltages without change of polarity).

Component supplier

  • Tell the vehicle manufacturer which of your circuits have pulsating DC voltages (alternating voltages without change of polarity).

Technical service / Approval authority

  • For the “Specific voltage condition”, check pulsating DC voltages (alternating voltages without change of polarity) against the DC threshold.

See every change side by side

RegVault customers compare every version of UN regulations, read the consolidated text and download the PDF.

ⓘ This report gives advice only. It is not legal or type-approval advice.

More UN R153 change reports

All UN R153 change reports